Call 0804897385286% Response Rate
Send E-mail

Thyristor Power Controllers

Our product range includes a wide range of hi-8003a40 analog thyristor power controller, hi-8003-tp-c3-ed analog thyristor power controller and hi-8003m thyristor based digital power controller.
Get CALLBACK

HI-8003A40 Analog Thyristor Power Controller

HI-8003A40 Analog Thyristor Power Controller
 
Get Best Quote
Approx. Rs 15,000 / Piece
Get Latest Price

Product Details:
BrandHeatcon
Model Name/NumberHI-8003A40
Frequency50 Hz
SCR ConfigurationFull Converter Suitable for Phase Angle Control
Maximum Power Handling5 kW
Maximum Load Current40A
Max. Controlling Input20 mA
DC Voltage10 V
Voltage230V AC +/- 10%
Mode of ControlPhase Angle Control
PhaseSingle Phase
Min. Controlling Input4 mA

Features:
  • Soft Start & Soft End: In soft start the output is given to the load in an exponential way. This character prevents excess inrush current to the heaters or transformers. This feature increases the life of the load. 
  • Over-Load Trip: Over-load trip can be adjustable from 110% to 200% of the rated output value. If over-load occurs the output is disabled. 
  • Automatic Reset: When over-load trip happens, after three seconds delay thyristor again starts normally and provides output. If over-load trip happens more than three times with in 10mins, the output is disabled permanently. 
  • Reset Switch: If any problem occurs in the output or input, and output is disabled, then hootter goes on. At this stage rectify the problem and press the reset switch. Enable switch: optional enable switch is also provided. 
Yes! I am Interested
Get CALLBACK

HI-8003-TP-C3-ED Analog Thyristor Power Controller

HI-8003-TP-C3-ED Analog Thyristor Power Controller
 
Get Best Quote
Approx. Rs 15,000 / Piece
Get Latest Price

Product Details:
BrandHeatcon
Model Name/NumberHI-8003-TP-C3-ED
Frequency50 Hz
Operating Voltage415V
Power HandlingMaximum 100 kW
Controlling Input20 mA
Maximum Load Current300A
Type of ConnectionStar/Delta
Mode of ControlPhase Angle Control
SCR ConfigurationFull Converter Suitable For Phase Angle Control
Phase3 Phase
Type Of LoadResistive / Inductive

Features:

  • Soft Start & Soft End: In soft start the output is given to the load in an exponential way. This character prevents excess inrush current to the heaters or transformers. This feature increases the life of the load.
  • Over-Load Trip: Over-Load trip can be adjustable from 110% to 200% of the rated output value. If Over-Load occurs the output is disabled.
  • Automatic Reset: When Over-Load trip happens, after three seconds delay thyristor again starts normally and provides output. If overload trip happens more than three times within 10 mins, the output is disabled permanently.
  • Reset Switch: If any problem occurs in the output or input, and output is disabled, then hotter goes on. At this stage rectify the problem and press the reset switch.
  • Enable Switch: Optional Enable Switch is also provided.

Specifications:
  • Controlling Input: 4-20 mA (0-10V DC)
Yes! I am Interested
Get CALLBACK

HI-8003M Thyristor Based Digital Power Controller

HI-8003M Thyristor Based Digital Power Controller
 
Get Best Quote
Approx. Rs 15,000 / Piece
Get Latest Price

Product Details:
BrandHeatcon
Model Name/NumberHI-8003M
Frequency50 Hz
SCR ConfigurationFull Converter Suitable for Phase Angle Control
Min. Controlling Input4 mA
DC Voltage10 V
Max. Controlling Input20 mA
Mode of ControlPhase Angle Control
Type of LoadResistive/Inductive
Maximum Load Current50A
Power HandlingMax 30 kW
Phase2 Phase
Voltage440V AC +/- 10%

Features:
  • Soft Start & Soft End: In soft start the output is given to the load in an exponential way. This character prevents excess inrush current to the heaters or transformers. This feature increases the life of the load. 
  • Over-Load Trip: Over-load trip can be adjustable from 110% to 200% of the rated output value. If over-load occurs the output is disabled. 
  • Automatic Reset: When over-load trip happens, after three seconds delay thyristor again starts normally and provides output. If over-load trip happens more than three times with in 10mins, the output is disabled permanently. 
  • Reset Switch: If any problem occurs in the output or input, and output is disabled, then hootter goes on. At this stage rectify the problem and press the reset switch. Enable switch: optional enable switch is also provided. 
Yes! I am Interested
Explore More Products
X
Find UsVyshak R.J (Director) Heatcon Sensors (P) Ltd
No. 155, Near Raghavendra Dhama, Byalakere - Silvepura Road, Hesaraghatta Hobli, Bengaluru - 560089, Karnataka, India
SEND SMS
SEND E-MAIL